First check that kicks in is current:
|
||||
Protection_Current (310) amperes or sth
|
||||
Present_Current, compared against protection crrent
|
||||
Over_Current_Protection_Time, how long until you shut it down
|
||||
|
||||
make a quick update about this
|
||||
|
||||
variables of interest are
|
||||
Max_Torque_Limit = 1000,
|
||||
Present_Load = 1000-something, which triggered the overload torque mechanism
|
||||
Overload_Torque = 80, how much of the max torque limit do we allow?
|
||||
Protection_Time = 200, after how long do we set Torque_Enable to 1? *not true lol
|
||||
Protective_Torque = 20, after we trigger the safety mechanism, how much torque do we allow the motor to have?
|
||||
|
||||
theres actually no temperature or voltage check that the feetechs perform, the only two are current and torque, which works like i said above
|
||||